North Seeker Series

Need Any Help?

If you have any questions or other customized requirement, contact us for more details.

Timing Frequency Series

SDI-316H-B

The positioning and directional frequency standard time code reference station can provide a highly stable first-level clock synchronization signal based on NTP/SNTP protocol standard time and self-perfection monitoring.

The device provides four 1PPS (TTL level) outputs, one serial port monitoring output, one network monitoring output, one NTP output, six IRIG-B outputs (RS422), eight 100MHz frequency outputs, one positioning serial port, and one differential data output.

Features

  • High integration
  • High precision
  • Flexible configuration

Application

  • UAV ground station & Measurement and control vehicles
  • Communication vehicle, radar vehicle
  • CH4、CH5 Measurement and control platform

Physical and electrical

Voltage 220VAC, 50Hz
Power ≤20W
Dimensions 8.9cm×48.3cm×41.5cm
Weight ≤6.6kg
Warranty One year

Performance

Channel BDS:B1I,B2I,B3I
GPS:L1C/A,L1C,L1P,L2C,L2P,L5
GLONASS:G1,G2
GALILEO:E1,E5a,E5b
QZSS:L1C/A,L1C,L2C,L5
Position Accuracy ≤1.5m (1σ)
IRIG-B (DC) 4 RS-422
≤20ns (1σ)
1PPS 4 LVTTL
≤20ns (1σ)
Heading accuracy 0.1°(2m baseline)
Pitch/Roll accuracy 0.3°(2m baseline)
Communication Ports 2 RS422 1 Ethernet (10/100Mbps)
Output power 10dBm±2dBm
Phase noise(SSB) ≤-110dBc/Hz@10Hz
≤-120dBc/Hz@100Hz
≤-125dBc/Hz@1KHz
Short-term stability ≤9E-12/1s
Frequency accuracy <≤1E-12 (after 24hrs)
Output Frequency 8 100MHz (Sine)
Amplitude ≥+5dBm (Load 50Ω)

Environmental

Operating -45℃~+60℃
Storage -55℃~+70℃
Humidity GJB1621.7A-2006
Vibration GJB 150.16A-2009
Shock GJB 150.18A-2009